Seismic damper systems are designed to improve a building’s structural integrity and to reduce the impact of ground movement on it in the event of an earthquake. Typically, seismic dampers are integrated into a building at the point of construction and often require a power source. Professor Moussa Leblouba, who works at the Department of Civil and Environmental Engineering at the University of Sharjah in the United Arab Emirates, was intent on fixing some of the problems inherent to existing damper systems.
“The device was first conceived in early 2016,” he explains. “I developed it to solve a few problems with existing dampers, such as fluid leakage, the need for complete replacement after experiencing one earthquake, and the active damper’s dependence on electrical power.
“What I have created is a passive damper. It consists of a steel cylinder filled with small steel balls. A shaft with short rods protruding radially from it passes through the cylinder and its two ends extend outside of it and connect to the structure.
“When an earthquake shakes the building, the shaft moves back and forth along the cylinder. The rods are dragged through the balls, and the friction between them converts the seismic energy into heat. The structure, therefore, has to absorb less of the energy, and the damage to beams, columns and connections is reduced.”
This device can be installed after a building is constructed, making it suitable for retrofitting, as well as for new construction.